  1.  
  2.               SuperMATCH Thunder/24 EISA
  3.  
  4.                 Release Notes
  5.  
  6.                     23 April 1993
  7.  
  8. These release notes contain the latest information about installing and
  9. operating your new Thunder/24 for Microsoft Windows graphics card and
  10. software.
  11.  
  12. The first section is a copy of the printed release notes included with the
  13. card.  The second section is a more detailed explanation of some of these 
  14. items.
  15.  
  16.  
  17. 1.  Requirements
  18.  
  19.     The Thunder/24 drivers require a 80386 based CPU or better, and are
  20.     fully supported only in Windows 386 Enhanced mode.
  21.  
  22.  
  23. 2.  Unnamed floppy prompt
  24.  
  25.     If you attempt to install the Thunder/24 software from your B: floppy,
  26.     you will see the prompt "Please insert the .", due to a bug in the
  27.     Windows SETUP program.  Type "B:\" (or the name of the disk drive 
  28.     holding the Thunder/24 install disk), then click OK.
  29.  
  30.  
  31. 3.  Third-party "shell" programs
  32.  
  33.     If you are using a third-party shell program, such as the Norton Desktop
  34.     for Windows, and you experience problems while installing Thunder/24
  35.     software, refer to the detailed section later in this file.
  36.  
  37.  
  38. 4.  Quarterdeck QEMM
  39.  
  40.     The QEMM "stealth" feature interferes with the Confidence Test portion of
  41.     the Thunder/24 installation program.  If you are using this feature of
  42.     QEMM, refer to the detailed section later in this file.
  43.  
  44.  
  45. 5.  Applications with difficulties at 24 bits
  46.  
  47.     - The Program Manager in Windows 3.1 will cause errors if you attempt to 
  48.       add the Thunder/24 applications to a large group.  See the detailed 
  49.       section later in this file.
  50.  
  51.     - The Microsoft Visual C++ setup program attempts to create a large group
  52.       and will issue two errors.  See the detailed section later in this file.
  53.  
  54.     - The "Aquatic Realm" and "Swan Lake" screen saver modules in After Dark
  55.       2.0 display strange bitmaps on devices with 24 bits of color depth.
  56.       Release 2.0a of After Dark solves this problem.  Contact Berkeley
  57.       Systems Technical Support at 1-800-877-5535 for this upgrade.
  58.  
  59.     - You shouldn't use full-screen mode in Microsoft MediaPlayer on non-VGA 
  60.       devices.  See the detailed section later in this file.
  61.  
  62.  
  63. 6.  Compaq Prosignia with motherboard SCSI
  64.  
  65.     If you intend to install your Thunder/24 in a Compaq Prosignia system
  66.     using a SCSI disk and the on-board SCSI controller, you need to take
  67.     an additional step after installing your Thunder/24 but before actually
  68.     using the board.  Refer to the detailed section later in this file.
  69.  
  70.  
  71. -------- Details ---------
  72.  
  73.  
  74. This file contains notes and information relating to the Windows driver
  75. installation and usage which might not have made it into the release
  76. documentation.
  77.  
  78.  
  79. 1. Restrictions
  80.  
  81.  
  82. The Thunder/24 drivers require an 80386 CPU or better, and are fully supported
  83. only in Windows 386 Enhanced mode.  Our experience has shown that the driver
  84. operates correctly in Windows Standard mode only if an extended memory manager
  85. (such as EMM386 or QEMM) is NOT used. Thunder/24 will not operate at all in 
  86. Windows 3.0 Real mode.
  87.  
  88. Ordinarily, this does not present a problem.  Most 386 users use Enhanced mode.
  89. However, when you perform an initial Windows installation, you must select a
  90. VGA device as your initial graphics adapter when performing an initial
  91. Windows installation.  Then, once Windows has been installed, you may use the 
  92. Thunder/24 Setup utility to change to the Thunder/24 adapter.
  93.  
  94.  
  95.  
  96. 2. Quarterdeck QEMM
  97.  
  98.  
  99. A UAE or GPF may occur during the confidence test if you include QEMM386.SYS 
  100. in your CONFIG.SYS file.  QEMM's "stealth" feature, invoked with a "st:m" or 
  101. "st:f" option, causes the EISA BIOS memory space to be remapped.  If a GPF 
  102. occurs, perform these steps:
  103.  
  104.     . Edit CONFIG.SYS and add "x=F000-FFFF" to the QEMM386.SYS line
  105.     . Reboot your computer
  106.     . Re-run the Thunder/24 installation procedure
  107.     . Edit CONFIG.SYS and remove the "x=F000-FFFF"
  108.  
  109. The QEMM "stealth" feature only interferes during the confidence test, and
  110. will not affect normal operation of the card.
  111.  
  112.  
  113.  
  114. 3. Installation Notes
  115.  
  116.  
  117. . Unnamed floppy prompt
  118.  
  119.     Because of a bug in the Windows SETUP utility, if you are installing 
  120.     Thunder/24 from your B: floppy, you might be prompted with the particularly
  121.     unfriendly message "Please insert the ." If you receive this prompt, type 
  122.     in "B:\", or the path to the floppy disk drive holding the Thunder/24 
  123.     install disk if you are using a different drive.
  124.  
  125. . Third-party "Shell" Programs
  126.  
  127.     The Thunder/24 installation and setup program communicates with the Windows
  128.     Program Manager to install the Thunder/24 group and program icons.  Some
  129.     third-party shells, such as Norton's Desktop for Windows, do not fully
  130.     comply with the Program Manager DDE interface, and will produce a system
  131.     error during the Thunder/24 installation.
  132.  
  133.     To work around this problem, either change the SHELL line in your
  134.     SYSTEM.INI file to read "SHELL=PROGMAN.EXE" and restart Windows, or
  135.     launch PROGMAN.EXE from your preferred shell.  Then, restart the 
  136.     Thunder/24 installation.
  137.  
  138.  
  139. 4. Applications with difficulty at 24 bits per pixel
  140.  
  141.  
  142. Some applications have difficulty operating on a true-color device with 24
  143. bits per pixel.  Here are some of the applications which are known to have
  144. difficulty.
  145.  
  146. . Program Manager
  147.  
  148.     All of the bitmaps for all of the icons within a Program Manager group must 
  149.     fit within a single 64K segment.  Because of this, at 24 bits per pixel a
  150.     single group can hold at most 19 icons.  Attempting to add the 20th icon to
  151.     a group results in a message box indicating "Insufficient Memory to 
  152.     complete the operation."  The only solution to this is to split the group 
  153.     into two smaller groups.
  154.  
  155. . Microsoft Visual C++
  156.  
  157.     As one of the last steps in its setup process, Microsoft Visual C++
  158.     creates a program group with 22 icons.  Because of the Program Manager 
  159.     limitation described above, the addition of last two icons will generate 
  160.     errors.  Microsoft is aware of this problem and will be issuing a 
  161.     corrective update.
  162.  
  163.     In the interim, one solution is to create another group by hand
  164.     called "Visual C++ Doc", then move (using drag-and-drop) all the 
  165.     documentation related icons to this new group.  Then you may add the two 
  166.     icons which fail: MFCNOTES.HLP and MFCSAMP.HLP, both in the MSVC\HELP 
  167.  
  168. . Berkeley Systems After Dark 2.0
  169.  
  170.     The "Aquatic Realm" and "Swan Lake" screen saver modules in After Dark 2.0 
  171.     display very strange bitmaps on devices with 24 bits of color depth.  
  172.     Release 2.0a of After Dark solves this problem.  Contact Berkeley Systems 
  173.     Technical Support at 1-800-877-5535 for this upgrade.
  174.  
  175. . Microsoft MediaPlayer
  176.  
  177.     The Microsoft MediaPlayer application, when playing back Video for Windows
  178.     AVI files, has an option to play video clips at full screen.  This option
  179.     bypasses Windows to force the VGA into a non-standard mode.  Spectrum/24
  180.     will yield the display to the VGA while the clip is playing, but never
  181.     receives a signal when the clip is finished.  Thus, your screen will
  182.     continue to display the final AVI frame forever, and your system will
  183.     appear to be hung.  In fact, Windows is still running, and you should be
  184.     able to hit Alt-F4 and Enter until Windows exits back to DOS.
  185.  
  186.     The interim solution is to only use full-screen mode when you are running
  187.     a VGA driver.  Microsoft is aware of the problem and is working on a
  188.     permanent solution.
  189.  
  190.  
  191. 5.  Compaq Prosignia with motherboard SCSI
  192.  
  193.  
  194. There is a bug in the ROM BIOS for the on-board SCSI controller on all
  195. Compaq Prosignia systems.  This bug results in the upper half of one of
  196. the 80486 32-bit registers (EAX) getting lost during a SCSI hardware 
  197. interrupt, which can occur at any time.  This bug manifests itself as a
  198. General Protection Fault in THUNWIN.DRV when the mouse is being moved while
  199. the screen is refreshing at the same time disk activity is going on.
  200.  
  201. Compaq is currently working on update to their ROM BIOS, and has a corrective
  202. patch disk available through their technical support.  Until you receive
  203. that update, you can use the "CPQSCSI.COM" program which is installed in 
  204. the system\supermac subdirectory of your Windows directory by the Thunder/24
  205. installation program.  You need to include a line invoking CPQSCSI in your
  206. AUTOEXEC.BAT file.  You must inform CPQSCSI of the IRQ number that your
  207. SCSI controller is using; you can find out the IRQ number by running your
  208. EISA configuration utility.  The default IRQ is 15; if this is the case
  209. for you, include a line in your AUTOEXEC.BAT reading:
  210.  
  211.     c:\windows\system\supermac\cpqscsi 15
  212.  
  213. This program takes up only a few bytes of memory, and saves and restores
  214. all of the 32-bit registers around each SCSI hardware interrupt.
  215.  
  216. If you need assistance with this procedure, contact SuperMatch technical
  217. support.
  218.  
  219.  
  220. 6.  Usage of I/O ports.
  221.  
  222. In some cases, in can be useful to know exactly which I/O ports your
  223. peripheral devices use.  This can be especially helpful when attempting to
  224. isolate port conflicts.
  225.  
  226. The Thunder/24 EISA card uses the 32 I/O ports in the range zC80 through zC9F, 
  227. where "z" is the number of the EISA slot where the Thunder/24 resides.  For
  228. example, if your Thunder/24 EISA is installed in slot 4, the card will use 
  229. I/O ports 4C80, 4C81, 4C82, and so on through 4C9F.  Because ALL of our I/O 
  230. ports exist in the EISA I/O space for our particular slot, if none of your 
  231. cards violate the EISA specification in this regard, there should be no
  232. possibility of an I/O port conflict.
  233.  
  234. Thunder/24 EISA uses no IRQs or DMA lines.
  235.  
  236.  
  237. 7. NEC EISA Systems
  238.  
  239. Some revisions of NEC motherboards and CPU boards incorrectly limit the bus 
  240. address space to the lower 64 megabytes.  This is in violation of the EISA
  241. specification, and prevents installation of the Thunder/24, since all our
  242. possible addresses are above 64MB.
  243.  
  244. NEC is aware of the problem; their more recent motherboards and CPU boards
  245. extend the address range to 256MB.  This does not solve the general case, but 
  246. it does permit installation of Thunder/24 at 0F00,0000 (240MB).
  247.  
  248. If you are experiencing problems with an NEC EISA system, you will need to 
  249. contact their National Service Response Center at 1-800-388-8888.  Press 3 
  250. once the message starts.  You will need to inform them of your date of 
  251. purchase, serial number, and model number of the unit experiencing trouble.
  252. with.
  253.  
  254. You will need to replace both your motherboard and CPU board with A73 
  255. Enhanced parts.  The following are the earliest versions which allow 
  256. 256MB addressing, although later revisions may be in place at this time:
  257.  
  258.             Rev #    Part Number
  259.     Motherboard:    D7B    158-053306-003
  260.     CPU Board:    C8A    136-263293-501A
  261.  
  262. The BIOS version should be 1.00.40 or later, and the System Configuration 
  263. Utility (SCU) should be 3.03.01 or later.
  264.  
  265. NEC has informed us that these modifications will be handled as a warranty 
  266. repair even if your warranty has expired.  If the service personnel at NEC's 
  267. National Service Responce Center require a technician's name, refer them to 
  268. Jim Galvin at 508-635-4755.